we are facing problem of high skin temeprature in one of the pass of CDU charge heater (106,000BBl) refinery. After thermography, it shows even more. we have done following actions:
1. PUT manual the FC for that pass and manually maximized the flow through this pass only.
2. shut off the burner adjacent to this burner.
3. can not do the decoking for the crude heater. Furnace's Pigging is planned next year (2016).
But now, we are going to inject the LP steam online into one of the pass. LP steam is used only in case of:
- Furnace tripped due to pass flow low low.
- Furnace tube fire case.
What possible outcomes we can expect with this activity? will it benefit? is there any other technique to remove spalling?
Outcome:
Thanks for valuable comments.
In recent shutdown (planned turnedaround of the plant), we have managed to perform pigging of crude heater and after that, results are much better. no more skin temp issues. We have done pigging for pass more time, tube conditions are normal now.