I am working as production Engineer in FCC block which consists of FCC and LPG Treater unit.
LPG treater treats cracked LPG from FCC and Delayed coker Unit.IT has capacity of treating 404 m3/hr.We are experiencing a peculiar problem these days. Our LPG is getting contaminated with light yellow colour at the outlet of LPG treater unit. LPG ex FCC and coker unit is clear and having no signs of yellowish colour but at outlet it is failing. Copper strip corrosion and weathering tests are absolutely fine.
The following are the observations --
1) These units are commissioned 6 months ago and we didn't come across DSO formation in DSO settler but LPG quality is ok (Probably due to low mercaptans load in LPG, DSO is not forming in the process)
2) The lean amine H2s loading in FCC & DCU LPG washing is around 1200 -2400 ppm. May be noted here that on earlier occasions with this loading of amine,the downstream treater unit was giving good LPG wrt all lab tests.
3)The only problem is with colouring with which we are struggling.
4) sometimes we experience yellowish colour at the unit inlet of LPG treater.Even at the outlet of FCC & DCU also.But the colour is not that much remarkable.But in treater outlet the pale yellow/dark yellow colour is visible upon complete evaporation of LPG.Sometimes 0.5 to 0.1 ml of yellow residue is left and sometimes not.
5) We took complete shutdown of unit, depressurised, all caustic drained from system and vessels and fibre film contactors were water washed and again took the system inline but the yellowish colour in the system LPG still coming.The custic regenration is good and quality is good and copper corrosion test is ok.
The reason for yellowishness we unable to find out.
Can anyone share their experiences in dealing with this type of typical problem in MERICHEM section of caustic wash of LPG?