I am working at UOP Cyclemax CCR Platforming Unit having R-134 Catalyst. We are facing problem of high HCL in recycle gas. Can Anybody who has worked on same CCR Unit with R-134 Catalyst, share his experience?
Additional:
Thanks for responding. 1- Our stripper operation is OK regarding reflux ratio & bottom temperature, but the question is if Organic Chlorides are slipping from stripper, then Chloride level on spent catalyst in Platformer Reactors should also increase with high HCL in recycle gas that is not in our case. 2- We are trying to maintain Chloride level b/w 1.1~1.3 wt% by injecting PCE (perchloroethylene) more than design in oxychlorination zone but result always remained b/w 1.1~1.20 wt% on regenerated catalyst & 0.90~1.0 wt% on spent catalyst. Surface area value of Catalyst about 6 months ago was 152 m2/gm while we have changed our whole catalyst in last Turn Around in March,2012 & total 215 regeneration cycles have passed. 3- We have already changed reduction zone vent from upstream of product separator to upstream of Net Gas Compressor. Waiting for your valuable next response.