Q & A > Question Details
how can we see the astm and tbp curves for outlet streams in distillation units in hysys?
 
Answers
17/02/2011 A: Rajkumar Chate, Sulzer, rajkumar.chate@sulzer.com
Go to tools menu then click on utility, then add utility as distillation, then separate window will open in which select the stream for which you want to see the distillation. it will show you ASTM D86, D1160, TBP and D2887.
09/08/2010 A: Shaik Afzal, Texas A&M University, shaik.afzal.chem@gmail.com
Double-click on the stream, select Attachments tab. Click Utilities tab and select create. Select bp curves and click add utilities. click performance and, then, plots to get the required data.