Q & A > Question Details
What is the standard value of sox/nox in atmosphere if emitting from hydrogen generation unit reformer for fg/naphtha/off gas firing?
 
Answers
16/05/2011 A: keith bowers, B and B Consulting, kebowers47@gmail.com
1) There is no 'standard value.' The amount of SOX is directly linked to sulfur content of the fuel.
2) NOx values are highly dependent on burner design and presence or lack of catalytic de-NOX equipment. Nitrogen in the fuel also converts to NOx