In coker with more than one module, according to the experience in their units, how much does the performance of liquid products decrease when a module goes out of service?
Coking
Answers
28/08/2019
A:
niranjan puttaraju, GS E&C, niranjanmurthyp@gmail.com
At fixed feed quality, Coker yields mainly depend on 3 operating parameters, which are Coke Drum top pressure/ CokeDrum top temperature and recycle ratio. If you maintain these three parameters consistently then the yield in coke drum overhead will remain same. However, you may see a change in liquid yields due to poor separation, which is dependent on your fractionator temperature and pressure profile.
28/08/2019
A:
niranjan puttaraju, GS E&C, niranjanmurthyp@gmail.com
At fixed feed quality, coker yields mainly depend on 3 operating parameters which are Coke Drum top pressure/ CokeDrum top temperature and recycle ratio. If you are maintaining these three parameters consistently then the yield in the coke drum overhead will remain same. However, you may see a change in liquid yields due to poor separation, which is dependent on your fractionator temperature and pressure profile.